{"product_id":"indicador-de-corriente-pce-n30p","title":"PCE-N30P Current Indicator","description":"\u003cdiv\u003e\u003cstrong\u003eCurrent indicator for single-phase measurement \n\t\t\tof parameters such as voltage, current, power, phase angle... \/\n                        optional pulse output and RS485 interface \/ IP 65 front\u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e\n    \t\t\t\t\t\tThe PCE-N30P panel indicator is an \n    \t\tinstallation indicator that records and displays important parameters of \n    \t\ta single-phase network. The PCE-N30P panel indicator calculates \n    \t\tapparent, active, and reactive power, phase angle, and power factor \n    \t\tfrom current and voltage measurements. It also calculates the average power \n    \t\tover 15 minutes and the average voltage over 10 minutes. Parameterization \n    \t\tand operation are carried out using the four keys on the front of the device. \n    \t\tThe measuring ranges of the panel indicator (current 5 A, voltage \n    \t\t400 V) can be extended with a voltage and current converter. The \n    \t\tdecimal point is automatically adjusted according to the measured value. \n    \t\tThe two alarm outputs, included in the basic version, trigger an alarm if \n    \t\tlimit values are exceeded. In addition, the display color of the measured value \n    \t\tchanges when the alarm is activated. The pulse output (optionally available) \n    \t\tgenerates 5000 pulses per kWh. With the RS485 interface (optionally available) \n    \t\tyou can also select the measured values.\u003c\/div\u003e\u003cdiv\u003e\n\u003cdiv\u003e\n                         - Measurement and display of 16 parameters\u003cbr\u003e- IP 65 front\u003cbr\u003e- Tri-color display\n                         \u003c\/div\u003e\n\u003cdiv\u003e\n                         - Two alarm outputs\u003cbr\u003e- Adjustable current \/ voltage ratio\u003cbr\u003e- Optional RS-485 interface\n                         \u003c\/div\u003e\n\u003c\/div\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs\u003c\/td\u003e\n\u003ctd\u003e\n \t\t\t\t\t\tCurrent: 0.02 ... 6 A\u003cbr\u003e\n \t\t\t\t\t\tVoltage: 0 ... 480 V\u003cbr\u003e\n \t\t\t\t\t\tFrequency: 45.00 ... 100.00 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eVoltage, current, frequency: 0.2 %\u003cbr\u003e\n                        Active, apparent, reactive power: 0.5 %\u003cbr\u003e\n                        Power factor: 0.5 %\u003cbr\u003e\n                        Phase shift: 1 %\u003cbr\u003e\n                        Active energy, reactive energy: 0.5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e5 digits 7-segment, tri-color\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n                        Power consumption               \u003c\/td\u003e\n\u003ctd\u003e\n                        6 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n                        Outputs\u003c\/td\u003e\n\u003ctd\u003e\n     2 alarm relays 250 V \/ 0.5 A NO\u003cbr\u003e\n                        Optional:\u003cbr\u003e\n                        Analog output (0\/4 ... 20 mA or 0 ... 10 V)\u003cbr\u003e\n                        RS485 interface,\u003cbr\u003e\n                        Pulse output (5000 pulses\/kWh)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient temperature\u003c\/td\u003e\n\u003ctd\u003eOperating temperature: -25 °C ... 55 °C\u003cbr\u003e\n \t\t\t\t\t\tStorage: -33 °C ... +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e96 x 48 x 93 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel cutout dimensions\u003c\/td\u003e\n\u003ctd\u003e92 x 45 mm (according to DIN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n                        Power supply\u003c\/td\u003e\n\u003ctd\u003e85 ... 253 V AC (45 ... 65 Hz) or DC\u003cbr\u003e\n                        20 ... 40V AC (45 ... 65 Hz) or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n                        Protection type\u003c\/td\u003e\n\u003ctd\u003eFront: IP 65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eMounting clips with retaining screws,\n    \t\t\t\t\tconnection via terminal blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n                        Standards\u003c\/td\u003e\n\u003ctd\u003e\n                        \t\t\t\t\t\tEN 61010-1 CAT III 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cdiv\u003e\n\u003cstrong\u003eDelivery content\u003c\/strong\u003e\u003cbr\u003e\n                         1 x PCE-N30P Panel Indicator\u003cbr\u003e\n\t\t\t\t\t\t\t1 x Mounting material\u003cbr\u003e\n\t\t\t\t\t\t\t1 x User manual\u003c\/div\u003e","brand":"PCE INSTRUMENTS","offers":[{"title":"Default Title","offer_id":53888160923971,"sku":"PCE-N30P-1","price":247.44,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0755\/8866\/5667\/files\/1984847_833787_af7efaa9-d91d-4842-a046-9935d0db8fab.jpg?v=1763132935","url":"https:\/\/vichome.es\/en\/products\/indicador-de-corriente-pce-n30p","provider":"VicHome","version":"1.0","type":"link"}